The SIP package is one of four solver packages for MODFLOW supported by GMS.

Contents

Maximum Iterations Per Time Step

This value is the maximum number of times through the iteration loop in one time step in an attempt solve the system of finite-difference equations.

Number of Iteration Parameters

Five variables are generally sufficient.

Acceleration Parameter

This value must be greater than zero and is usually 1.0.

Head Change Criterion For Convergence

When the maximum absolute value of head change from all cells during an iteration is less than or equal to the head change criterion, solver iteration stops.

Print Out Interval

The maximum absolute head change is printed for each iteration of a time step whenever the time step is an even multiple of the print out interval. The printout also occurs at the end of each stress period regardless of the print out interval.

Iteration Parameter Seed

These options control the seed for calculating iteration variables. You can either specify the seed yourself or have MODFLOW calculate it.

Reset

This button will change all options to the default state.