This dialog allows the user to specify global output options for the simulation. This controls the datasets created by the engine which consist of spatially and temporally varied quantities (values per cell at each output time value).
These output datasets are stored in an XMDF solution file.
Output Times Lists
Due to the potentially long simulation times, CMS-Flow does not output at a constant interval during the simulation. Instead, the user defines one or more lists of times. For each dataset output by the engine, the user selects one time list. The selected quantity will be saved at each time in the time list.
- Lists: CMS-Flow supports up to four different and individual sets of time values.
- Output Times: The times included in the selected time list are displayed in this window.
- Type: The user adds and removes times to/from a time list using the tools in the time type section.
Output Datasets
CMS-Flow can output each of the following quantities. For each quantity, a time list must be specified. Selecting "None" turns off the output of that quantity.
- Water surface elevation
- Velocity
- Morphology
- Transport
- Simulation label: All datasets created by the model will be labeled with a simulation label and quantity label. This edit field allows specification of the simulation label.