GMS:MF6 UZF Package: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
No edit summary
No edit summary
Line 1: Line 1:
{{MODFLOW 6 Beta}}
{{MODFLOW 6 Beta}}
{{MODFLOW 6 Links}}
{{MODFLOW 6 Links}}
[[File:MF6-UZF package.png|thumb|400px|right|The ''Unsaturated Zone Flow (UZF)'' dialog]]
[[File:MF6-UZF package v2.png|thumb|400px|right|The ''Unsaturated Zone Flow (UZF)'' dialog]]
The ''Unsaturated Zone Flow (UZF) Package'' dialog is accessed by double-clicking on the WEL package under a MODFLOW 6 simulation in the Project Explorer. It contains the following sections and options:
The ''Unsaturated Zone Flow (UZF) Package'' dialog is accessed by double-clicking on the WEL package under a MODFLOW 6 simulation in the Project Explorer. It contains the following sections and options:
*''Sections'' list – A list of sections that can be turned on or off:
*''Sections'' list – A list of sections that can be turned on or off:
**''Comments'' – Turn on to make the ''Comments'' section visible.
**''COMMENTS'' – Turn on to make the ''COMMENTS'' section visible.
**''Options'' – Turn on to make the ''Options'' section visible.
**''OPTIONS'' – Turn on to make the ''OPTIONS'' section visible.
**''Data'' – Turn on to make the ''Data'' section visible. This section is on by default.
**''DATA'' – Turn on to make the ''DATA'' section visible. This section is on by default.
*''Comments'' section – Enter general alphanumeric comments. Comments entered here get written at the top of the file, preceded by a '#' symbol.
*''COMMENTS'' section – Enter general alphanumeric comments. Comments entered here get written at the top of the file, preceded by a '#' symbol.
*''Options'' section – Temporal options and settings:
*''OPTIONS'' section – Temporal options and settings:
**'''Auxiliary Variables...''' – Click to bring up the [[#Auxiliary Variables Dialog|''Auxiliary Variables'' dialog]].
**''AUXILIARY'' – Click the '''Auxiliary Variables...''' button when this is turned on to bring up the [[#Auxiliary Variables Dialog|''Auxiliary Variables'' dialog]].  
**'''Time Series...''' – Click to bring up the [[#Time Series Files Dialog|''Time Series Files'' dialog]].  
**''AUXMULTNAME'' – Use auxiliary variable as multiplier. Name of auxiliary variable to be used as multiplier of GWF cell area used by UZF cell.
**'''Observations...''' – Click to bring up the [[#Observation Files Dialog|''Observation Files'' dialog]].  
**''BOUNDNAMES'' – Allow boundary names. Turn on to indicate that the list of UZF cells will be provided with the associative boundary names.
**''AUXMULTNAME'' – The name of the auxiliary variable.
**''PRINT_INPUT'' – Print input to listing file. Turn on to write the list of UZF information to the listing file immediately after it is read.
**''BOUNDNAMES'' – If turned on, indicates that the list of UZF cells will be provided with the associative boundary names.
**''PRINT_FLOWS'' – Print input to listing file. Turn on to write the list of UZF flow rates to the listing file.
**''PRINT_INPUT'' – If turned on, indicates that the list of UZF information will be written to the listing file after it is read.
**''SAVE_FLOWS'' – Save flows to budget file. Turn on to write UZF flow terms to a specified file.  
**''PRINT_FLOWS'' – If turned on, indicates that a list of UZF flow rates will be printed to the listing file.
**''BUDGET FILEOUT'' – Allows the specification of a binary output file to which desired flow terms will be written.
**''SAVE_FLOWS'' – If turned on, indicates that the UZF flow terms will be written to a specified file.
**''PACKAGE_CONVERGENCE FILEOUT'' – Save package convergence info to a CSV file.
**''BUDGET_FILEOUT'' – Allows the specification of a file to which desired flow terms will be written.
**''TS6 FILEIN'' – Define time series files. Click the '''Files...''' button when this is turned on to bring up the [[#Time Series Files Dialog|''TS6 FILEIN Files'' dialog]].
**''MOVER'' – When turned on, indicates that the Unsaturated Zone Flow (UZF) Package, in this instance can be used in collaboration with the Water Mover (MVR) Package.
**''OBS6 FILEIN'' – Define observation files. Click the '''Files...''' button when this is turned on to bring up the [[#Observation Files Dialog|''OBS6 FILEIN Files'' dialog]].
**''MOVER'' – Can be used with the Water Mover (MVR) package. Turn on to allow this instance of the Unsaturated Zone Flow Package to be used in collaboration with the Water Mover (MVR) Package.  
**''SIMULATE_ET'' – If turned on, this indicates that ET will be simulated.
**''SIMULATE_ET'' – If turned on, this indicates that ET will be simulated.
**''LINEAR_GWET'' – If turned on, indicates that groundwater ET will be simulated.
**''LINEAR_GWET'' – If turned on, indicates that groundwater ET will be simulated.
**''SQUARE_GWET'' – If turned on, indicates that groundwater ET will be simulated by assuming a constant ET rate.
**''SQUARE GWET'' – If turned on, indicates that groundwater ET will be simulated by assuming a constant ET rate.
**''SIMULATE_GWSEEP'' – If turned on, indicates that groundwater discharge to land surface will be simulated.
**''SIMULATE_GWSEEP'' – If turned on, indicates that groundwater discharge to land surface will be simulated.
**''UNSAT_ETWC'' – If turned on, indicates that ET in the unsaturated zone will be simulated as a function of the specified PET rate.
**''UNSAT_ETWC'' – If turned on, indicates that ET in the unsaturated zone will be simulated as a function of the specified PET rate.
**''UNSAT_ETAE'' – If turned on, indicates that ET in the unsaturated zone will be simulated simulated using a capillary pressure based formulation.
**''UNSAT_ETAE'' – If turned on, indicates that ET in the unsaturated zone will be simulated simulated using a capillary pressure based formulation.
*''Data'' section – Contains the following:
*''DATA'' section – Contains the following:
**''Periods'' drop-down – Use the '''Increment Up and Down''' [[File:Increment up and down arrows.png|14px]] buttons to select the desired period.
**''Periods'' drop-down – Use the '''Increment Up and Down''' [[File:Increment up and down arrows.png|14px]] buttons to select the desired period.
**'''Define Period''' [[File:Add Note Icon.svg|14px]] – If no period is defined, click to make the spreadsheet editable.
**'''Define Period''' [[File:Add Note Icon.svg|14px]] – If no period is defined, click to make the spreadsheet editable.
Line 34: Line 35:
***'''Delete from Just This Period''' – Click to delete matching stresses from just this period.
***'''Delete from Just This Period''' – Click to delete matching stresses from just this period.
**'''Plot All Periods''' [[File:Mf6time-series.svg|14px]] – Click to bring up the [[GMS:XY Series Editor|''XY Series Editor'' dialog]]. Requires that a cell be selected in the table.
**'''Plot All Periods''' [[File:Mf6time-series.svg|14px]] – Click to bring up the [[GMS:XY Series Editor|''XY Series Editor'' dialog]]. Requires that a cell be selected in the table.
**'''Open Time Series''' [[File:Open Macro.svg|14px]] – Click to bring up the he [[GMS:XY Series Editor|''XY Series Editor'' dialog]].
**'''Open Time Series''' [[File:Open Macro.svg|14px]] – Click to bring up the  
**'''Filter on Selected Cells''' [[File:Mf6filter.svg|14px]] – If UGrid cells are selected when the dialog is opened, this button causes the table to only display those rows that correspond to the selected cells.
<!-- **'''Filter on Selected Cells''' [[File:Mf6filter.svg|14px]] &ndash; Click to turn on filtering on the selected cells. -->
**Table &ndash; Allows the manual input of different variables for the UZF Package.
**Table &ndash; Allows the manual input of different variables for the UZF Package. Contains the following:
***''IUZNO'' &ndash; An integer value that defines the UZF cell number associated with the specified PERIOD data on the line.
***''IUZNO'' &ndash; An integer value that defines the UZF cell number associated with the specified PERIOD data on the line.
***''FINF'' &ndash; A value that defines the applied infiltration rate of the UZF cell.
***''FINF'' &ndash; A value that defines the applied infiltration rate of the UZF cell.
Line 45: Line 46:
***''HROOT'' &ndash; A value that defines the root potential of the UZF cell.
***''HROOT'' &ndash; A value that defines the root potential of the UZF cell.
***''ROOTACT'' &ndash; A value that defines how much root activity exists in the UZF cell.
***''ROOTACT'' &ndash; A value that defines how much root activity exists in the UZF cell.
*** ''AUX'' &ndash; These columns represent the values of the auxiliary variables for each unsaturated zone flow, which previously may have been created if the ''AUXILIARY'' option was set.
{{Auxiliary Variables Dialog}}
{{Auxiliary Variables Dialog}}
{{MF6 Time Series Files Dialog}}
{{MF6 Time Series Files Dialog}}

Revision as of 00:01, 20 January 2022

MODFLOW 6
Models & Tools
GWF Model
GWT Model
Cell Properties Dialog
Zone File
Packages
Flow: GNC, HFB, NPF
GWF: BUY, CHD, CSUB,
DRN, EVT, GHB,
LAK, MAW, MVR,
OBS, RCH,RIV,
SFR, STO, UZF,
WEL
GWT: ADV, CNC, DSP
FMI, IC, IST, LKT,
MDT, MST, MVT,
MWT, OBS, SFT,
SRC,SSM, UZT
Other DIS, DISU, DISV,
IMS, OC, TDIS,
PEST

The Unsaturated Zone Flow (UZF) dialog

The Unsaturated Zone Flow (UZF) Package dialog is accessed by double-clicking on the WEL package under a MODFLOW 6 simulation in the Project Explorer. It contains the following sections and options:

  • Sections list – A list of sections that can be turned on or off:
    • COMMENTS – Turn on to make the COMMENTS section visible.
    • OPTIONS – Turn on to make the OPTIONS section visible.
    • DATA – Turn on to make the DATA section visible. This section is on by default.
  • COMMENTS section – Enter general alphanumeric comments. Comments entered here get written at the top of the file, preceded by a '#' symbol.
  • OPTIONS section – Temporal options and settings:
    • AUXILIARY – Click the Auxiliary Variables... button when this is turned on to bring up the Auxiliary Variables dialog.
    • AUXMULTNAME – Use auxiliary variable as multiplier. Name of auxiliary variable to be used as multiplier of GWF cell area used by UZF cell.
    • BOUNDNAMES – Allow boundary names. Turn on to indicate that the list of UZF cells will be provided with the associative boundary names.
    • PRINT_INPUT – Print input to listing file. Turn on to write the list of UZF information to the listing file immediately after it is read.
    • PRINT_FLOWS – Print input to listing file. Turn on to write the list of UZF flow rates to the listing file.
    • SAVE_FLOWS – Save flows to budget file. Turn on to write UZF flow terms to a specified file.
    • BUDGET FILEOUT – Allows the specification of a binary output file to which desired flow terms will be written.
    • PACKAGE_CONVERGENCE FILEOUT – Save package convergence info to a CSV file.
    • TS6 FILEIN – Define time series files. Click the Files... button when this is turned on to bring up the TS6 FILEIN Files dialog.
    • OBS6 FILEIN – Define observation files. Click the Files... button when this is turned on to bring up the OBS6 FILEIN Files dialog.
    • MOVER – Can be used with the Water Mover (MVR) package. Turn on to allow this instance of the Unsaturated Zone Flow Package to be used in collaboration with the Water Mover (MVR) Package.
    • SIMULATE_ET – If turned on, this indicates that ET will be simulated.
    • LINEAR_GWET – If turned on, indicates that groundwater ET will be simulated.
    • SQUARE GWET – If turned on, indicates that groundwater ET will be simulated by assuming a constant ET rate.
    • SIMULATE_GWSEEP – If turned on, indicates that groundwater discharge to land surface will be simulated.
    • UNSAT_ETWC – If turned on, indicates that ET in the unsaturated zone will be simulated as a function of the specified PET rate.
    • UNSAT_ETAE – If turned on, indicates that ET in the unsaturated zone will be simulated simulated using a capillary pressure based formulation.
  • DATA section – Contains the following:
    • Periods drop-down – Use the Increment Up and Down Increment up and down arrows.png buttons to select the desired period.
    • Define Period Add Note Icon.svg – If no period is defined, click to make the spreadsheet editable.
    • Delete Period GMS Delete Icon.svg – Click to delete the existing period.
    • Add Rows Row-add.svg – Click to bring up the Add Stresses dialog.
    • Delete Rows Row-delete.svg – Click to bring up a dialog with three options:
      • Delete from All Periods – Click to delete matching stresses from all periods.
      • Delete from Just This Period – Click to delete matching stresses from just this period.
    • Plot All Periods Mf6time-series.svg – Click to bring up the XY Series Editor dialog. Requires that a cell be selected in the table.
    • Open Time Series Open Macro.svg – Click to bring up the
    • Table – Allows the manual input of different variables for the UZF Package. Contains the following:
      • IUZNO – An integer value that defines the UZF cell number associated with the specified PERIOD data on the line.
      • FINF – A value that defines the applied infiltration rate of the UZF cell.
      • PET – A value that defines the ET rate of the UZF cell and specified GWF cell.
      • EXDP – A value that defines the ET extinction depth of the UZF cell.
      • EXTWC – A value that defines the amount of water removed from the UZF cell through evapotranspiration.
      • HA – A value that defines the amount of potential air that enters the UZF cell.
      • HROOT – A value that defines the root potential of the UZF cell.
      • ROOTACT – A value that defines how much root activity exists in the UZF cell.
      • AUX – These columns represent the values of the auxiliary variables for each unsaturated zone flow, which previously may have been created if the AUXILIARY option was set.

Auxiliary Variables Dialog

The Auxiliary Variables dialog

The Auxiliary Variables dialog is accessed by clicking Auxiliary Variables... in the Options section of many package dialogs. It is used to define an array of one or more auxiliary variable names. It contains the following sections and buttons:

  • At the top is an unlabeled section listing all of the variables, one per line. Double-click on a variable name to rename it.
  • Insert Row Row-insert.svg – Click to insert a row above the currently-selected row.
  • Add Row Row-add.svg – Click to add a row below the currently-selected row.
  • Delete Row Row-delete.svg – Click to delete the selected row.
  • Move Up Row-up.svg – Move the selected row up.
  • Move Down Row-down.svg – Move the selected row down.

Note that each variable name must be unique. If two or more variables share a name, variables added since opening the dialog will not be saved.

Time Series Files Dialog

The Time Series Files dialog

The Time Series Files dialog is accessed by clicking Time Series Files... in the Options section of many of the package dialogs. It is used to define an array of one or more time series files. It contains the following sections and buttons:

  • At the top is an unlabeled section listing all of the time series files, one per line.
    • Double-click on the first field to see the full file path and name.
    • Click Edit... to open the time series file.
  • Insert Row Row-insert.svg – Click to insert a row above the currently-selected row.
  • Add Row Row-add.svg – Click to add a row below the currently-selected row.
  • Delete Row Row-delete.svg – Click to delete the selected row.
  • Move Up Row-up.svg – Move the selected row up.
  • Move Down Row-down.svg – Move the selected row down.


Observation Files Dialog

The Observation Files dialog

The Observation Files dialog is accessed by clicking Observations... in the Options section of many of the package dialogs. It is used to define an array of one or more observation files. It contains the following sections and buttons:

  • At the top is an unlabeled section listing all of the observation files, one per line.
  • Insert Row Row-insert.svg – Click to insert a row above the currently-selected row.
  • Add Row Row-add.svg – Click to add a row below the currently-selected row.
  • Delete Row Row-delete.svg – Click to delete the selected row.
  • Move Up Row-up.svg – Move the selected row up.
  • Move Down Row-down.svg – Move the selected row down.


Add Stresses Dialog

The Add Stresses dialog for the HFB package

The Add Stresses dialog is accessed by clicking Add Rows Row-add.svg in the Periods section of several MODFLOW 6 package dialogs. It contains the following sections and options:

  • Table – Table Options differ according to each package. See chart below.
  • Number of rows to add – Use the Increment Up and Down Increment up and down arrows.png buttons to select the desired number of rows to add.
  • Add to section – Radio buttons with the following options:
    • All defined periods – Select to add the rows to all defined periods.
    • Only this period – Select to add the rows to only this period.
Package Add Stresses Dialog Table Options
CHD
CHD Options
  • LAY – Used to specify certain layers.
  • ROW – Used to specify certain rows.
  • COL – Used to specify certain columns.
  • HEAD – Represents the head at the boundary.
DRN
DRN Options
  • LAY – Used to specify which layer is being applied.
  • ROW – Used to specify which row is being applied.
  • COL – Used to specify which column is being applied.
  • ELEV – Represents the elevation of the drain.
  • COND – Represents the hydraulic conductance between the aquifer and the drain.
GHB
GHB Options
  • LAY – Used to specify certain layers of the module.
  • ROW – Used to specify which row is being applied.
  • COL – Used to specify which column is being applied.
  • BHEAD – Represents the boundary head.
  • COND – Represents the hydraulic conductance between the aquifer cell and the boundary.
HFB
HFB Options
  • LAY1 – Represents the first of two chosen layers.
  • ROW1 – Represents the first of two chosen rows.
  • COL1 – Represents the first of two chosen columns.
  • LAY2 – Represents the second of two chosen layers.
  • ROW2 – Represents the second of two chosen rows.
  • COL2 – Represents the second of two chosen columns.
  • HYDCHR – The hydraulic characteristic of the horizontal-flow barrier. When this variable is negative it multiplied by the conductance of two cells.
LAK
LAK Options
  • LAKENO_OUTLETNO – A value that defines the reach number associated with the specified PERIOD data.
  • SETTING – Information that is linked to keywords and values.
  • VALUE1 – Value to be entered in relation to the specific project.
  • VALUE2 – Value to be entered in relation to the specific project.
MAW
MAW Options
  • WELLNO – A value that defines the reach number associated with the specified PERIOD data.
  • MAWSETTING – Information that is linked to keywords and values.
  • VALUE1 – Value to be entered in relation to the specific project.
  • VALUE2 – Value to be entered in relation to the specific project.
  • VALUE3 – Value to be entered in relation to the specific project.
RIV
RIV Options
  • LAY – Used to specify which row is being applied.
  • ROW – Used to specify which row is being applied.
  • COL – Used to specify which column is being applied.
  • STAGE – Variable that represents the head in the river.
  • COND – Variable that represents the riverbed hydraulic conductance.
  • RBOT – Variable that represents the elevation of the bottom of the riverbed.
SFR
SFR Options
  • RNO – A value that defines the reach number associated with the specified PERIOD data.
  • SFRSETTING – Information that is linked to keywords and values.
  • VALUE1 – Value to be entered in relation to the specific project.
  • VALUE2 – Value to be entered in relation to the specific project.
UZF
UZF Options
  • IUZNO – An integer value that defines the UZF cell number associated with the specified PERIOD data on the line.
  • FINF – A value that defines the applied infiltration rate of the UZF cell.
  • PET – A value that defines the ET rate of the UZF cell and specified GWF cell.
  • EXDP – A value that defines the ET extinction depth of the UZF cell.
  • EXTWC – A value that defines the amount of water removed from the UZF cell through evapotranspiration.
  • HA – A value that defines the amount of potential air that enters the UZF cell.
  • HROOT – A value that defines the root potential of the UZF cell.
  • ROOTACT – A value that defines how much root activity exists in the UZF cell.
WEL
WEL Options
  • LAY – Represents which layer within the grid to which the chosen well will be assigned.
  • ROW – Represents which row within the grid to which the chosen well will be assigned.
  • COL – Represents which column within the grid to which the chosen well will be assigned.
  • Q – Represents the volumetric well rate at which the recharge (positive value) and discharge (negative value) of the well will be.


Related Topics