SMS:STWAVE Menu: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
No edit summary
No edit summary
 
(24 intermediate revisions by the same user not shown)
Line 1: Line 1:
The items in the [[SMS:STWAVE|STWAVE]] menu in the [[SMS:Cartesian Grid Module|Cartesian Grid Module]] are described  below:
The STWAVE model makes use of right-click menus in the simulation.


* [[SMS:Spectral  Energy|Spectral Energy]] – opens the ''Spectral Energy'' dialog.
==STWAVE Simulation Menu==
* [[SMS:STWAVE Cell Attributes|Assign Cell Attributes]] – opens the ''STWAVE Cell Attributes'' dialog.
The following menu commands are available in the [[SMS:STWAVE|''STWAVE'']] menu:
* [[SMS:STWAVE Model Control|Model  Control]] – opens the ''STWAVE Model Control'' dialog.
* Run STWAVE – launches the finite element analysis engine.


==Run STWAVE==
; Delete : Removes the selected simulation.
; Duplicate : Creates a copy of the selected simulation.
; Rename : Allows changing the name of the selected simulation.
; Simulation Run Queue :
; '''Model Control''' : Opens the [[SMS:STWAVE Model Control|''STWAVE Model Control'']] dialog.
; '''Model Check''' : Starts the [[SMS:Model Checker|model checker]].
; Save Simulation : Creates all of the input files needed for the STWAVE model run.
; Run Simulation : Runs the STWAVE engine and generates output files. See below for more information.
; Save Project, Simulation and Run: Save the SMS project, exports the STWAVE input files, and starts the STWAVE engine to generate the solution files.
; Read Solution : Opens a browser to import STWAVE solution files.
; Properties :
 
===Run Simulation Command===
After a simulation has been read or saved, SMS can launch the finite element analysis engine. To run [[SMS:STWAVE|STWAVE]]:
After a simulation has been read or saved, SMS can launch the finite element analysis engine. To run [[SMS:STWAVE|STWAVE]]:
# Select ''STWAVE'' | '''Run STWAVE'''. A dialog  appears showing the engine that will execute.
# Right-click on the STWAVE simulation and select '''Run Simulation''' or '''Save Project, Simulation and Run'''. The ''Simulation Run Queue'' dialog  appears showing the engine that will execute.
# If the executable program is the wrong version, or if you are given the  message that it was not found, then click the file browser icon and choose the correct version of the program that should run.
#* If the executable program is the wrong version, or if given the  message that it was not found, then click the file browser icon and choose the correct version of the program that should run.
# Click the ''OK'' button or press the ''ENTER'' key.
# When STWAVE has finished, the solution can be added to the project by clicking the '''Load Solution''' button.
 
A window will appear which displays various information as [[SMS:STWAVE|STWAVE]] runs. You should not need to type anything in this window. If the window prompts you for filenames, you need an updated version of the STWAVE model executable. When [[SMS:STWAVE|STWAVE]] has finished, you will be prompted to press the ''ENTER'' key. If the window goes away before doing this, [[SMS:STWAVE|STWAVE]] encountered a problem and crashed.
The ''Simulation Run Queue'' window will appear which displays various information as [[SMS:STWAVE|STWAVE]] runs. Normally it is not necessary to type anything in this window. Using the ''Simulation Run Queue'' multiple simulations can run at the same time.
 


==Related Topics==
==Related Topics==
* [[SMS:STWAVE|STWAVE]]
* [[SMS:STWAVE|STWAVE]]




Line 22: Line 32:
{{Template:Navbox SMS}}
{{Template:Navbox SMS}}


[[Category:STWAVE]]
[[Category:SMS Menus|S]]
[[Category:SMS Menus]]
[[Category:SMS Boundary Conditions|S]]
[[Category:STWAVE|M]]

Latest revision as of 20:36, 22 March 2022

The STWAVE model makes use of right-click menus in the simulation.

STWAVE Simulation Menu

The following menu commands are available in the STWAVE menu:

Delete
Removes the selected simulation.
Duplicate
Creates a copy of the selected simulation.
Rename
Allows changing the name of the selected simulation.
Simulation Run Queue
Model Control
Opens the STWAVE Model Control dialog.
Model Check
Starts the model checker.
Save Simulation
Creates all of the input files needed for the STWAVE model run.
Run Simulation
Runs the STWAVE engine and generates output files. See below for more information.
Save Project, Simulation and Run
Save the SMS project, exports the STWAVE input files, and starts the STWAVE engine to generate the solution files.
Read Solution
Opens a browser to import STWAVE solution files.
Properties

Run Simulation Command

After a simulation has been read or saved, SMS can launch the finite element analysis engine. To run STWAVE:

  1. Right-click on the STWAVE simulation and select Run Simulation or Save Project, Simulation and Run. The Simulation Run Queue dialog appears showing the engine that will execute.
    • If the executable program is the wrong version, or if given the message that it was not found, then click the file browser icon and choose the correct version of the program that should run.
  2. When STWAVE has finished, the solution can be added to the project by clicking the Load Solution button.

The Simulation Run Queue window will appear which displays various information as STWAVE runs. Normally it is not necessary to type anything in this window. Using the Simulation Run Queue multiple simulations can run at the same time.

Related Topics