SMS:Q&A FESWMS

From XMS Wiki
Revision as of 16:18, 11 December 2017 by Jcreer (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search

Return to the Main Q&A Page

Q: Does FESWMS work with piers.

A: FESWMS version 3.3.2 does not work with piers. FESWMS version 3.3.3 fixed the issue with Piers but does not work with transient models. It is unknown what is wrong specifically other than models that run using 3.3.2 do not always work with 3.3.3. The problem seems to be that the model doesn't work with transient models.

Q: Can FESWMS be used to model sediment transport.

A: Test cases using equilibrium inflow and clear water inflow have been successful in modeling sediment transport. Attempts to create test cases using the other options have been unsuccessful.