GMS:MT3DMS Point Sources/Sinks BC: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
No edit summary
No edit summary
 
(14 intermediate revisions by 3 users not shown)
Line 1: Line 1:
The [[GMS:Source/Sink Mixing Package|Source/Sink Mixing Package]] dialog can be used to edit both point and areal sources/sinks using a spreadsheet. In many cases, it is more convenient to view and edit source sink concentrations on a cell-by-cell basis. Two commands are provided to facilitate this type of editing: the Point Sources/Sinks command and the Areal Sources/Sinks command.
{{MT3DMS Links}}
[[File:MT3DMS PointSourceSinks.png|thumb|450 px|The ''MODFLOW/MT3DMS Source/Sinks'' dialog showing point options for MT3DMS]]
The [[GMS:MT3DMS_Source/Sink_Mixing_Package|''Source/Sink Mixing Package'']] dialog can be used to edit both point and areal sources/sinks using a spreadsheet. In many cases, it is more convenient to view and edit source sink concentrations on a cell-by-cell basis. Two commands are provided to facilitate this type of editing: the '''Point Sources/Sinks''' command and the '''Areal Sources/Sinks''' command.


==Point Sources/Sinks==
==Point Sources/Sinks==
The '''Point Sources/Sinks''' command is used to assign and edit the concentrations at point sources and sinks. Before selecting the '''Point Sources/Sinks''' command, a set of cells should be selected using the cell selection tools. Once the command is selected, the MT3DMS Point Source/Sink dialog appears.
The '''Point Sources/Sinks''' command is used to assign and edit the concentrations at point sources and sinks. Before selecting the '''Point Sources/Sinks''' command, a set of cells should be selected using the cell selection tools. Once the command is selected, the ''MT3DMS Point Source/Sink'' dialog appears.


A point source/sink concentration for each species is assigned to the selected cells by selecting the toggle corresponding to the type of source/sink. The concentration at the cells can be specified as either constant or transient. If a constant value is specified, this number will be used for all stress periods. If the Variable option is used, clicking on the window brings up the XY Series Editor. The [[XY Series Editor|XY Series Editor]] is used to assign a concentration value for each stress period.
A point source/sink concentration for each species is assigned to the selected cells by selecting the toggle corresponding to the type of source/sink. The concentration at the cells can be specified as either constant or transient. If a constant value is specified, this number will be used for all stress periods. If the ''Variable'' option is used, clicking on the window brings up the ''XY Series Editor''. The [[XY Series Editor|''XY Series Editor'']] is used to assign a concentration value for each stress period.


===Multiple Sources/Sinks per Cell===
===Multiple Sources/Sinks per Cell===
Line 13: Line 15:


==Areal Sources/Sinks==
==Areal Sources/Sinks==
The '''Areal Sources/Sinks''' command is used to edit the concentrations assigned to recharge and evapotranspiration fluxes. Before selecting the '''Areal Sources/Sinks''' command, a set of cells should be selected using the cell selection tools. The concentration fluxes due to [[GMS:RCH Package|recharge]] and [[GMS:EVT Package|evapotranspiration]] are applied to vertical columns rather than to individual cells. Therefore, to edit the value for a vertical column, any cell in the column can be selected. Once the '''Areal Sources/Sinks''' command is selected, the MT3DMS Areal Sources/Sinks dialog appears.
The '''Areal Sources/Sinks''' command is used to edit the concentrations assigned to recharge and evapotranspiration fluxes. Before selecting the '''Areal Sources/Sinks''' command, a set of cells should be selected using the cell selection tools. The concentration fluxes due to [[GMS:RCH Package|recharge]] and [[GMS:EVT Package|evapotranspiration]] are applied to vertical columns rather than to individual cells. Therefore, to edit the value for a vertical column, any cell in the column can be selected. Once the '''Areal Sources/Sinks''' command is selected, the ''MT3DMS Areal Sources/Sinks'' dialog appears.


The areal source/sink concentration values at the selected cells can be edited by highlighting a species and either selecting a constant value for all stress periods, or by defining a set of values.  
The areal source/sink concentration values at the selected cells can be edited by highlighting a species and either selecting a constant value for all stress periods, or by defining a set of values.


==See also==
==See also==
Line 23: Line 25:


{{Navbox GMS}}
{{Navbox GMS}}
[[Category:MT3DMS]]
[[Category:MT3DMS|point]]
[[Category:PHT3D|point]]
[[Category:MT3DMS Dialogs|Point]]

Latest revision as of 16:27, 15 November 2017

MT3DMS
Pre-processing
MT3DMS Commands
Building an MT3DMS Simulation
MT3DMS Packages
ICBUND Array
Saving an MT3DMS Simulation
Post-processing
MT3DMS Display Options
Importing an MT3DMS Simulation
Calculate Mass
Tutorials
MT3DMS Tutorials
Packages
Basic Transport Package Dialog
MT3DMS Source/Sink Mixing Package
Chemical Reaction Package
Transport Observation Package

The MODFLOW/MT3DMS Source/Sinks dialog showing point options for MT3DMS

The Source/Sink Mixing Package dialog can be used to edit both point and areal sources/sinks using a spreadsheet. In many cases, it is more convenient to view and edit source sink concentrations on a cell-by-cell basis. Two commands are provided to facilitate this type of editing: the Point Sources/Sinks command and the Areal Sources/Sinks command.

Point Sources/Sinks

The Point Sources/Sinks command is used to assign and edit the concentrations at point sources and sinks. Before selecting the Point Sources/Sinks command, a set of cells should be selected using the cell selection tools. Once the command is selected, the MT3DMS Point Source/Sink dialog appears.

A point source/sink concentration for each species is assigned to the selected cells by selecting the toggle corresponding to the type of source/sink. The concentration at the cells can be specified as either constant or transient. If a constant value is specified, this number will be used for all stress periods. If the Variable option is used, clicking on the window brings up the XY Series Editor. The XY Series Editor is used to assign a concentration value for each stress period.

Multiple Sources/Sinks per Cell

In many cases, multiple point sources/sinks, each having a different type, can be assigned to an individual cell. In this case, the toggle for each type should be selected and the concentration specified. It is also possible for multiple sources/sinks of the same type to be assigned to a single cell. However, MT3DMS only allows one concentration to be assigned to each type for a single cell. In such cases, the specified concentration for that type applies to all sources/sinks of that type within the cell.

Fixing Concentrations for Selected Species

When entering the concentrations for a specified concentration cell, it is sometimes necessary to specify the concentrations of some of the species but allow the concentrations for the remaining species to vary. This can be accomplished by specifying a negative concentration for the species that are to vary.

Areal Sources/Sinks

The Areal Sources/Sinks command is used to edit the concentrations assigned to recharge and evapotranspiration fluxes. Before selecting the Areal Sources/Sinks command, a set of cells should be selected using the cell selection tools. The concentration fluxes due to recharge and evapotranspiration are applied to vertical columns rather than to individual cells. Therefore, to edit the value for a vertical column, any cell in the column can be selected. Once the Areal Sources/Sinks command is selected, the MT3DMS Areal Sources/Sinks dialog appears.

The areal source/sink concentration values at the selected cells can be edited by highlighting a species and either selecting a constant value for all stress periods, or by defining a set of values.

See also