SMS:TUFLOW Menu: Difference between revisions

From XMS Wiki
Jump to navigationJump to search
(Clarified different TUFLOW Menus)
(→‎TUFLOW Menu Bar Commands: Clarified the inactive cell -- in mesh option)
Line 38: Line 38:
; Cell Attributes : Enabled when one or more cells on a TUFLOW grid are selected. The attributes that can be set using this command are the cell code and the option to override the global initial water level (set in the 2D Model Control). The cell code options are:
; Cell Attributes : Enabled when one or more cells on a TUFLOW grid are selected. The attributes that can be set using this command are the cell code and the option to override the global initial water level (set in the 2D Model Control). The cell code options are:
*''active cell'': cell is part of calculations and the results grid domain; Cell Code = 1
*''active cell'': cell is part of calculations and the results grid domain; Cell Code = 1
*''inactive cell – in mesh''; cell is not part of the calculations, but is a part of the results grid domain, Cell Code = -1; because comparing two simulations in SMS requires the meshes have the same domain, this option is primarily used to keep the domain of two models the same for comparison while taking into account differences (e.g. areas of a floodplain that are raised to prevent flooding and are thus no longer included in the computation)
*''inactive cell – in mesh''; cell is not part of the calculations, but is a part of the results grid domain, Cell Code = -1; because comparing two simulations with the Data Calculator in SMS requires the SMS mesh results (*.2DM file) have the same domain, this option is primarily used to keep the model results compatible for comparison while taking the differences into account (e.g. areas of a floodplain that are raised to prevent flooding and are thus no longer included in the computation)
*''inactive cell – not in mesh'': cell is entirely removed from the computation and results, Cell code = 0
*''inactive cell – not in mesh'': cell is entirely removed from the computation and results, Cell code = 0
For SMS versions 11.1 and earlier the selected cells will only be used if ''Specify cell by cell'' is selected in ''Cell codes'' section of the [[SMS:TUFLOW Grid Options|''TUFLOW Grid Options'']] dialog.
For SMS versions 11.1 and earlier the selected cells will only be used if ''Specify cell by cell'' is selected in ''Cell codes'' section of the [[SMS:TUFLOW Grid Options|''TUFLOW Grid Options'']] dialog.

Revision as of 21:39, 27 September 2016

TUFLOW Simulation Menu

The TUFLOW Simulation menu is accessed by right-clicking on a TUFLOW simulation TUFLOW Simulation Project Explorer icon.png item (Sim) in the Project Explorer. The following menu commands are available:

Delete
Removes the TUFLOW simulation.
Duplicate
Creates another copy of the simulation.
Rename
Changes the name of the simulation.
Export TUFLOW files
SMS will save the TUFLOW input files in the TUFLOW directory for that simulation. If one does not already exist, a prompt will ask to select a location.
Launch TUFLOW
Launches TUFLOW using input files that have previously been exported.
Save Project, Export and Launch TUFLOW
Saves the project, writes out the TUFLOW input files, and launches TUFLOW.
2D Model Control
Brings up the 2D Model Control dialog where various model parameters are set. See TUFLOW 2D Model Control page.
1D Control
Brings up the Control 1D dialog where various model parameters are set. See Model Parameters page.
Model Check
Causes SMS to perform a check for invalid settings that could prevent TUFLOW from running properly. If errors are found, they will be reported in the Model Check dialog with information on how to correct them.

Components Menu

The TUFLOW Components menu is accessed by right-clicking on the TUFLOW Compenents folder in the Project Explorer. The following menu command is available:

New 2D Geometry Component
Creates a geometry components. The TUFLOW simulation can contain components. 2D Grids and certain map coverages can be linked to this component.

The component item also has a right-click menu with the following commands:

Delete
Removes the component.
Delete
Creates a copy of the component with all linked grids and coverages.
Rename
Changes the name of the component.
Add External Files
Launches a browser to add external files to the component.
Grid Options
Brings up the TUFLOW Grid Options dialog.

Material Sets Menu

The TUFLOW Material Set menu is accessed by right-clicking on the TUFLOW Material Set folder in the Project Explorer. The following menu command is available:

New Material Set
Creates a new material set. The TUFLOW simulation can contain multiple material sets.

The material set item also has a right-click menu with the following commands:

Rename
Changes the name of the material set.
Properties
Brings up the TUFLOW Material Properties dialog.
Delete
Removes the material set.
Export
Saves the material set as a TUFLOW Materials File (*.tmf).

TUFLOW Menu Bar Commands

The following commands are available in the TUFLOW menu in the menu bar when the Cartesian Grid Module is enabled and a cell or cells are selected in a TUFLOW grid.

File:TUFLOW Cell Attributes.jpg
TUFLOW Cell Attributes dialog
Cell Attributes
Enabled when one or more cells on a TUFLOW grid are selected. The attributes that can be set using this command are the cell code and the option to override the global initial water level (set in the 2D Model Control). The cell code options are:
  • active cell: cell is part of calculations and the results grid domain; Cell Code = 1
  • inactive cell – in mesh; cell is not part of the calculations, but is a part of the results grid domain, Cell Code = -1; because comparing two simulations with the Data Calculator in SMS requires the SMS mesh results (*.2DM file) have the same domain, this option is primarily used to keep the model results compatible for comparison while taking the differences into account (e.g. areas of a floodplain that are raised to prevent flooding and are thus no longer included in the computation)
  • inactive cell – not in mesh: cell is entirely removed from the computation and results, Cell code = 0

For SMS versions 11.1 and earlier the selected cells will only be used if Specify cell by cell is selected in Cell codes section of the TUFLOW Grid Options dialog.

Assign Material Type
This command is enabled when one or more cells on a TUFLOW grid are selected. The command will open the Materials Data dialog. The Materials Data dialog will allow selecting a material to assign to a cell. The material set for the cell will only be used if Specify cell by cell is selected in the Materials section of the TUFLOW Grid Options dialog.

Related Topics